4 Way Reversing Valves (DSF-4) Used in Air Conditioner
- The conversion of household heat pump air conditioner refrigeration and heating.
- Hot air type of defrost switch device of various refrigerators and dehumidifiers.
- Various freezers,showcase window defrost ice and thawing the conversion of the energy-saving circuit.
Technical Requirements
- Nominal capacity: 4.0KW
- Suitable power: 0.75-1.5HP
- Port size: 8.0mm
- High-pressure side interface port size(inch): 5/16,3/8
- Low-pressure side interface port size(inch):3/8
- Internal leakage:≤1.0L/min
- Applicable refrigerant:R22,R407C,R134a,R410A
- Maximum working pressure: R22,R407C,R134a:3.0MPA
- Operating pressure differential: Max:2.5/3.1MPA,MIN: 0.2MPA
- Matched coil voltage:
- Matched Coil(5-8w) allows maximum temperature: 130ºC
- Applicable fluid temperature: -20ºC~120ºC
- Applicable ambient temperature:-20ºC~+55ºC
Catalog No. | Port Size(mm) | Connection(inch) | O. P. D (Mpa) | Internal Leakage (ml/min) | Power | ||
P=1.0Mpa at 70Â | (TON) | ||||||
D | E. S. C | Max | Min | ||||
DSF-4U | Φ8 | 5/16,3/8 | 3/8 | 3.0/4.15 | 0.2 | < 1000 | 0.75-1.5 |
DSF-4 | Φ8 | 5/16,3/8 | 3/8 | ||||
DSF-9U | Φ11.1 | 3/8,5/16 | 1/2 | 3.0/4.15 | 0.25 | < 1500 | 0.75~2 |
DSF-9 | Φ11.1 | 3/8,5/16 | 1/2 | ||||
DSF-11 | Φ11.5 | 3/8,1/2 | 5/8,3/4 | 3.0/4.15 | 0.3 | < 2000 | 2~4 |
DSF-11U | Φ11.5 | 3/8,1/2 | 5/8,3/4 | ||||
DSF-20 | Φ15.5 | 1/2,5/8 | 3/4,7/8 | 3.0/4.15 | 0.34 | < 4000 | 2~8 |
DSF-20U | Φ15.5 | 1/2,5/8 | 3/4,7/8 | ||||
DSF-38 | Φ20 | 5/8,3/4,7/8 | 7/8,1-1/8 | 3.0/4.15 | 0.34 | < 6000 | 6~12 |
DSF-48 | Φ26 | 7/8,1-1/8 | 1-1/8,1-3/8 | 3.0/4.15 | 0.34 | < 8000 | 8~20 |
DSF-140 | Φ41 | 5/16,12/8 | 14/8 | 3.0/4.15 | 0.34 | < 10000 | 40 |
DRHF-4 | Φ8 | 3/8 | 3/8 | 3.0/4.15 | 0.2 | < 1000 | 0.75~1.5 |
DRHF-9 | Φ11 | 1/2 | 1/2 | 3.0/4.15 | 0.25 | <1500 | 0.75~3 |
DRHF-20 | Φ15.5 | 5/8 | 5/8 | 3.0/4.15 | 0.34 | <4000 | 2~8 |
DRHF-38 | Φ20 | 7/8 | 7/8 | 3.0/4.15 | 0.34 | <6000 | 6~12 |
DRHF-48 | Φ26 | 1-1/8 | 1-1/8 | 3.0/4.15 | 0.34 | <8000 | 8~20 |
Inserted Coil | AC220V,AC115V~120V,AC100V~110V,AC24V,AC220V~240V | ||||||
Wire Coil | AC220V,AC115V~120V,AC100V~110V,AC24V,AC220V~240V,AC265V~277V |





Testing Equipment of Elevator Guide Rail
Inspection Equipment of Elevator Guide Rail
Detection Equipment of Elevator Guide Rail
testing facility of Elevator Guide Rail
measuring equipment of Elevator Guide Rail
We carry high quality Testing Equipment Of Guide Rail for all major elevator and escalator brands
for OTIS Elevators, ThyssenKrupp Elevators, Schindler Elevators, KONE Elevators, Mitsubishi Elevators, Fujitec Elevators, Hitachi Elevators, Toshiba Elevators, Fuji Elevators, Express Elevators, Sigma Elevators, LG Elevators, Hyundai Elevators, BLT Elevators, CANNY Elevators, SJEC Elevators, KOYO Elevators
Testing Equipment Of Guide Rail
Testing Equipment of Elevator Guide Rail, Inspection Equipment of Elevator Guide Rail, Detection Equipment of Elevator Guide Rail
CEP Elevator Products ( China ) Co., Ltd. , https://www.china-elevators.com