Giq Type Pneumatic High Vacuum Butterfly Bamper Flap Valve
GIQ pneumatic high vacuum butterfly valve is to change the direction of gas path by electromagnetic reversing valve, and control the cylinder driven butterfly valve for opening and closing activities. Used to connect or cut off the air flow in a vacuum line. Applicable medium is pure air and non corrosive gas. Optional feedback signal assembly and electrical valve positioner.
Important technical performance
Â
Applicability | 105~1.3×10-4Pa |
Valve Leak Rate | ≤1.3×10-4Pa.L/S. |
Applicable Temperature | -25~+80ºC(Nitrile butadiene rubber) -30~+150ºC(fluoro rubber) |
Mains Voltage | 0.4~0.6MPa |
Mounting Direction | optional |
Important parts name
valve body,valve cover,valve rod:Â carbon steel or stainless steel
sealing parts:Â Nitrile butadiene rubber,fluoro rubber
Shape and connection size(mm)
Model | DN | D | Do | D1 | B | H | B1 | L | n-φc |
GID-40 | 40 | 85 | 70 | 44 | 22 | 162 | 90 | 104 | 4-φ7 |
GID-50 | 50 | 110 | 90 | 55 | 22 | 175 | 90 | 104 | 4-φ7 |
GID-65 | 65 | 125 | 105 | 70 | 26 | 198 | 102 | 140 | 4-φ9 |
GID-80 | 80 | 145 | 125 | 85 | 30 | 208 | 102 | 140 | 4-φ9 |
GID-100 | 100 | 170 | 145 | 105 | 30 | 220 | 102 | 140 | 4-φ12 |
GID-150 | 150 | 220 | 195 | 156 | 35 | 272 | 115 | 164 | 8-φ12 |
GID-200 | 200 | 275 | 250 | 208 | 40 | 330 | 205 | 190 | 8-φ12 |
GID-250 | 250 | 330 | 300 | 258 | 45 | 335 | 205 | 190 | 8-φ14 |
GID-300 | 300 | 380 | 350 | 308 | 55 | 426 | 152 | 247 | 8-φ14 |
GID-400 | 400 | 500 | 465 | 410 | 60 | 520 | 180 | 308 | 8-φ18 |
GID-500 | 500 | 600 | 565 | 510 | 80 | 643 | 220 | 378 | 12-φ18 |
GID-600 | 600 | 710 | 670 | 610 | 100 | 760 | 270 | 524 | 12-φ21 |
GID-800 | 800 | 920 | 815 | 815 | 130 | 962 | 320 | 648 | 20-φ21 |
GID-1200 | 1200 | 1440 | 1280 | 1280 | 150 | 1360 | 385 | 1480 | 36-φ19  |




Â
Ultra Low Temperature Infrared Pyrometer
This classification includes one color infrared pyrometers measuring range is 0℃-1000℃. The one color pyrometers currently on market are mostly narrow-band pyrometers. Its principle of temperature measurement is to determine the temperature by detecting the radiant energy that occurs in a narrow wavelength range (8-14μm for 0-1000C pyrometer) of an object. The temperature a pyrometer measured is the average temperature in an area, and the measuring result is affected by emissivity, lens contamination and background radiation.
To use 1-color pyrometer mode, the measured area of the object should be large (it can fully fill the target field of view) , object surface should be relatively flat (not curved), measurement direction should less than 30 degrees, and the physical and chemical state of the measured object surface should be stable (not in the process of oxidation, gasification or liquefaction) , the optical channel should with less dust and without blocking and attenuation.
Main applications include: inductioin heating,heat treatment,Galvanized wire ,also suitable for temperature measurement in a good environment. Products in this catalog are usually applied to metallurgical industry(rod and wire mills.Hot rolling mills), foundry, cement kiln, induction heating, heat treatment, heating furnace, vacuum furnace, monocrystalline silicon, polysilicon, semiconductor and other industrial temperature measurement.1000C infrared pyrometer, compact infrared pyrometer, small online infrared pyrometer
Changzhou Sijie Optoelectronics Technology Co.,Ltd. , https://www.sjinfrared.com