The magnetic stirrer is a kind of instrument product which is suitable for stirring the material in the solid-liquid mixture with a low viscosity or the physical magnetic force working in the liquid. In the daily time, the magnetic stirrer is damaged during the test. We need to calmly deal with, and can not be anxious, after some treatment methods and exclusion methods can determine the cause of the malfunction, so in the daily use of magnetic stirrer also must pay attention to some of the magnetic stirrer maintenance, as much as possible to extend the device Life expectancy.

1 , it is best not to let the instrument work without heated liquid.

2. Before the operation of the machine, it is necessary to check whether it is grounded, and ensure that the work can be performed only after completion.

3 , In order to ensure that the instrument is not damaged, usually there is insulating material inside the instrument. Therefore, when we first use the magnetic stirrer, we will find a little white smoke or a pungent taste. These are normal phenomena, not Product quality issues, keep the ventilation on it.

4 , the magnetic stirrer internal devices have an upper limit of heat, so be sure to take into account when heating, the best way is to ensure that the machine will not only heat, and remember to change the state of the motor into a rotating state, so that Maximize the magnetic stirrer.

5 , after the completion of the heating work, we must remember to turn off the heat first, wait a few minutes after almost the temperature has dispersed and then turn off the stirring.

6 , to ensure that the operating environment is dry, because in a humid environment, the instrument easily lead to leakage and other phenomena, which is why we must ensure that the instrument grounding, if the instrument is very wet, must use hot air to dry.

7 , must be careful during the operation, do not be burned, because the general temperature is relatively high.

8. For safety reasons, there is a fuse on the back of the instrument. When the device is still working after power on, it can be checked whether it needs to be replaced.

Holter ECG Monitoring System

Introduction

Holter ECG Monitoring Systems adopt 12-lead system of international standard, which can continuously record ECG waveform for 24-hour and analyze ECG waveform by the PC software. It is applicable for use in medical institution and community.


Analysis Software Function

1.The rate of checking RR wave up to 99.9%, which increased the accuracy of analysis without losing wave.

2.AI histogram function which can directly distinguish various abnormal ECG which can analyze faster.

3. Dynamic ECG [Channel Correct" function, which can correct mistakenly wearing that makes the analysis more accurate.

4.Lorenz and Demix analysis function, which can analyze more faster, more accurately. Single medical case can be completely analyzed in 10 min, which can reduce the physician`s work.

5.ST can be displayed in many kinds of form, which ensures that analyzing ST- Trends Diagram comprehensively, observing the whole or partial ST variety to analyze the specific area of myocardial ischemia.

6.Atrial fibrillation function can be recognized automatically and can distinguish atrial fibrillation case, give advice and generate analysis report .

7.Unique Cardiac Fatigue Index function, which can judge index of Cardiac Fatigue .High-risk groups can be found and early intervention treatment can be taken by the index, which can effectively judge the heart age and predict SCD (Sudden Cardiac Death).

8. P-wave analysis function, which can check cardiac arrhythmia (such as AVB).

9.According to the requirement of patients, options can be selected freely while printing report, which can save physician `s time

10. ECG can be printed by various forms according to the user`s requirement.

11.Pacemaker analysis function, which can analyze different pacemakers(such as AAI,VVI,DDD).

12.The comprehensive analysis system of stand-alone version with network version ,users can freely select any model.

13.Wire and wireless simultaneously transfer mode ,which reduce complicated performance.

14. Dynamic ECG and static ECG analysis system ,which reduced complex operations.

15. Time Domain and Frequency Domain function on HRV module can reflect the moderation effect of sympathetic and parasympathetic to the heart rate.

16.HRT function can predict myocardial infarction which has clinical value.

17.ST function which can check the exact time and length of myocardial ischemia in 24 hours.



Holter Monitor,Holter 24 Hours,Holter Recorder,Holter Ecg Monitoring System